RR18 Regulated DC-TO-DC Power Converter | 2-Channel, 180-Watt, 10–24 VDC

Product Description
The RR18, converts a wide input voltage range of 10–24 VDC to dual regulated 24 VDC outputs. The converter is capable of delivering 160 Watts and 25 watts continuously for an input voltage range of 10 to 24 VDC. The converter delivers at full load a minimum output voltage of 18 VDC at 8 VDC input voltage. The control circuitry includes use of a popular PWM for voltage regulation and output current limit. Protection circuitry includes the output over-voltage limit.
Features
Converts a wide input voltage range of 10–24 VDC to dual regulated 24 VDC outputs
Capable of delivering 160 Watts and 25 watts continuously
Delivers at full load a minimum output voltage of 18 VDC at 8 VDC input voltage
Control circuitry includes use of a popular PWM for voltage regulation and output current limit
Protection circuitry includes the output over-voltage limit
Specifications
Weight:
0.75 lb (340 g)
Dimensions:
1.76 x 2.20 x 5.00 in (44.7 x 55.9 x 127.0 mm)
Normal Voltage:
10 VDC to 24 VDC (for regulated output)
Output Voltage:
CH1 & CH2: 24 VDC regulated (for input voltage from 10 to 24 VDC) Greater than 18 VDC for input voltage of 8 VDC (follows the input voltage for input above 24 VDC)
Current:
CH1: 12.6 Amps typical at 14 VDC input voltage & at full load, 19 Amps maximum at 10 VDC input voltage & at full load, 0.05 Amps maximum at no load, 6.67 Amps Continuous at full load
CH2: 1.9 Amps typical at 14 VDC input voltage & at full load, 3.0 Amps maximum at 10 VDC input voltage & at full load, 0.05 Amps maximum at no load, 1.04 Amps Continuous at full load
Power:
CH1: 160 Watts continuous for Ein > 10 VDC
CH2: 25 Watts continuous for Ein > 10 VDC, 185 watts total continuous power (not to exceed)
Regulation:
CH1 & CH2:
2% for load, 1% for line (10–24 VDC), and 2% for temperature
Protection (OL):
Withstands, without damage or degradation, loads exceeding 100% full load. Output collapses to input when load exceeds approximately 190% of full load current. Unit delivers rated output upon removal of the overload (OL) condition.
Short Circuit (SC) Protection:
Unit is protected against output short circuit by the tripping of external input circuit breakers.
Efficiency:
90% minimum at 14 VDC input
Temperature:
-55ºC to 71ºC
Altitude:
55,000 ft
Compliance:
FAA TSO-C71
Product Codes
- Mfr Part No:RR18
- EDMO #:RR18
- Brand:K G S ELECTRONICS
- Category:Inverters & Converters
- ECCN:3A225
- SCHEDULE B CODE:8504.40.0018