PSD90-3 AC/DC Fuel Quantity Test Set

Product Description
The PSD90-3 will test any AC or DC capacitive fuel, water, liquid oxygen (LOX), or engine oil system. When combined with an aircraft specific interface, the PSD90-3 allows the user to test, troubleshoot and isolate fuel system issues, calibrate fuel quantity indicators, and detect contaminated fuel probes. Developed for use in all environments the PSD90-3 is ideal for flight line testing on battery power or bench testing on external power.
The PSD90-3 provides users with two methods; Auto and Manual, for detecting and isolating contaminated fuel probes caused by particulates, water, microbial growth, or other sources of contamination. During normal capacitance measurements, the contaminated fuel probe detection function will automatically alert the user via a Degree or Error indication on the display and with a Contaminated Fuel Probe Detected LED on the front panel. Once there is an indication of possible probe contamination, the user can manually test using the Check Probe function with a user-selectable Percent of Error limit which will illuminated the Contaminated Fuel Probe LED indicator if exceeded.
Features
Safe and precise measurement and simulation
Contaminated Probe Detection
Low Voltage / Low Current Mode - Isolates corroded connections.
Distance-to-Fault Measurement
Self-test on power up
Closed box calibration
Measurement of capacitance, DC voltage, insulation resistance, and Distance to Fault (DTF)
Simulation of capacitance for indicator testing
Automatic contaminated fuel probe detection while performing normal capacitance tests
Manual troubleshooting of contaminated fuel probes using the CHECK PROBE function
Low Voltage/Low Current Mode allows isolation of intermittent or corroded connections
Megger and capacitance manual ranging modes assist in finding intermittent faults
REV DC (DC+) Mode measures capacitance from the DC+ side of the tank unit for complete testing DC capacitive fuel systems
Compatible with existing aircraft fuel quantity system interfaces
Closed box calibration using front panel controls
Self-test on power-up
Rechargeable battery or externally powered
Intrinsically safe design
Optional OEM DC option emulates PSD30-2AF OEM DC operation and DC capacitive measurement values.
Specifications
Weight:
13 lbs (5.9 kg)
Dimensions:
10.6 x 14 x 6.5 in (26.9 x 35.6 x 16.5 cm)
Operating temperature:
-40°C to +55°C
Storage temperature:
-51°C to +71°C
Relative Humidity:
5 to 95% (non-condensing)
Altitude:
4600 m
Battery Type:
Rechargeable 12 V Lead Acid Gel Cell
Battery Operation:
12 hours minimum from -10°C to +50°C
Battery Charge Time:
8 hours max from fully discharged battery
EMC:
EN-61326
Safety:
UL-61010B-1, EN-61010-1, CSA 22.2 No 61010-111
Product Codes
- Mfr Part No:PSD90-3
- EDMO #:PSD90-3
- Brand:VIAVI
- Category:Fuel Quantity Test Sets
- SCHEDULE B CODE:9030.33.0040
- SCHEDULE B CODE:9030.33.0040