429 Databus Analyzer | with Williamsburg Protocol

Product Description
Features
- Lightweight handheld unit
- 16-line, backlit display
- User friendly operation with BITE Mode that ensures that messaging such as setup menus and help screens all display on the single screen; BITE mode supports systems on the 737-300, 747-400, MD-11, and A320/330/340
- Record up to 240 screens for later download to PC/printer
- Displays multiple labels simultaneously
- Fully compatible with all other DATATRAC test equipment and PC-based support programs
- Database conforms to 429-15 and includes Boeing labels for AVM, EIS, EICAS, FSEU, and FQIS
Specifications
Weight:
3.5 lb (1.6 kg)
Dimensions:
6.3 x 9.75 x 2 in (16 x 24.75 x 5 cm)
RECEIVER OPERATION:
Ports:
2
Bus Frequency:
12 kHz – 14.5 kHz or 100 kHz (selectable)
Input Levels:
6.5 VDC to 13.5 VDC (A to B)
Input Impedance:
12.0Ω
Word Update:
1 ms to 19 sec. update rate displayed as instantaneous, min. or max. value
Display Format:
Engineering units with pre-stored scaling based on equipment IDs, hexadecimal (full or data field), binary (full or data field), user-defined, graphic plots, or ASCII character
Maximum Words:
128 per channel
Transmit Word Gap:
4 bits
Dynamic Transmit:
Repeat patterns of ramps and flat segments; levels programmable between + full scale and segment times or 0 to 999.999 sec.
BREAKPOINT OPERATION:
Label Sequence:
A, B, A or B, A then B, B then A
Data Conditions:
EQ, NEQ, OR, GT, LT, /GT/, /LT/
Event Count:
1 to 99 before break
History:
Up to 24,540 words in a programmable window about the breakpoint; selectable time stamp
Trigger Pulse:
5V, 0.02 ms
RECORD OPERATION:
Channels:
up to 16 selectable labels
Sample Interval:
1 ms to 10 sec. (selectable)
Record Capacity:
120 kbytes (e.g. 85 hours of single label at 1/sec)
Playback Options:
graphic plots, data lists, DAC, RS-232C Bite Operation
BITE Formats:
Compatible with distributed and centralized BITE concept used on 747-400, 737-300, MD-11, A320, A330, and A340 aircraft
Menu Display:
Standard 14-line x 24-character menu with selectable menu choices
Simulation:
select NULL, DC1, DC2, or DC4 command outputs to simulate various flight phases
Maintenance Words:
displays 350/351 label maintenance bits; bit status along with pre-stored text presented
Recording Feature:
save up to 240 BITE screens for later viewing or downloading
Reference:
ARINC 429-15; Boing labels for AVM, EIS, FSEU, EICAS, and FQIS
Power Requirements:
110 or 220 VAC, 50 - 400 Hz AC Adapter, internal NiCad
Product Codes
- Mfr Part No:01-1404-01
- EDMO #:DT-400H-01
- Brand:ATG
- Category:Databus Analyzers